For more info: sales@tangkasanugerah.com
Technical Description
The experimental unit contains a blackbody emitter with a thermopile for the investigation of thermal radiation, a light source with luxmeter for illuminance measurements, and absorption plates with thermocouples for the investigation of Kirchhoff's laws. The intensity of thermal and visible radiation can be adjusted. Colour filters and apertures extend the range of experiments.
The measured values are displayed digitally on the measuring unit. At the same time, the measured values can also be transmitted directly to a PC via USB. The data acquisition software is included.
Learning Objectives / Experiments
- Lambert's cosine law
- inverse-square distance law (Lambert)
- Stefan-Boltzmann constant
- Kirchhoff's laws
* absorptivity
* reflectivity
* emissivity
Specification
[1] investigating thermal and visible radiation
[2] blackbody emitter with thermopile to investigate thermal radiation
[3] white light source with luxmeter to investigate visible radiation
[4] absorption plate and reflection plate fitted with thermocouples to investigate Kirchhoff's laws
[5] intensity of thermal radiator and light source adjustable
[6] 3 colour filters with holder (red, green, infrared), aperture
[7] luxmeter to measure the illuminance
[8] thermocouples to measure the temperature
[9] thermopile to measure the radiation capacity
[10] GUNT software for data acquisition via USB under Windows Vista or Windows 7
Technical Data
Thermal radiator
- power output: 400W
- max. temperature that can be reached: 300°C
- radiation surface area, LxW: 200x200mm
Light source
- power output of light bulb: 42W
- angle of rotation, both sides: 0...90°
- illuminated area
* ground glass, LxW: 193x193mm
* aperture, diameter: 25mm
Measuring ranges
- illuminance: 0...1000 Lux
- temperature: 2x 0...200°C
- radiation capacity: 0...1000W/m²
Dimensions and Weight
LxWxH: 1460x310x390mm (experimental setup)
LxWxH: 420x400x170mm (measuring amplifier)
Weight: approx. 30kg
Required for Operation 230V, 50/60Hz, 1 phase or 120V, 60Hz/CSA, 1 phase
Scope of Delivery
1 frame, 1 measuring amplifier
1 thermal radiator, 1 light source
1 luxmeter, 1 thermopile
2x absorption plate
2x reflection plate
3 colour filters with holder, 2x aperture
1 set of connecting cables
1 GUNT software CD + USB cable
1 manual