Technical Description
The heat transfer in and around pipes can be investigated using the WL 314.01.
The heat transfer from the pipe wall to the medium is observed. A ring heater simulates the flow inside the pipe, while a rod heater reflects the conditions in the flow around a pipe.
The power and surface temperature of the two electrical heaters are measured and displayed on the base unit WL 314.
Learning Objectives / Experiments
- consideration of the relationships between Nusselt, Reynolds and Prandtl
- determination of heat transfer coefficient
- calculation of the air velocity
Specification
[1] accessory for WL 314, parallel flow module
[2] 2 thermocouples type K: Temperature measurement at the top of the rod-type heater and at the inner surface of the ring heater
[3] mounted in WL 314 with quick-action fasteners
Technical Data
Air duct: D=60mm
Ring heater
- power: 220W
- diameter: 60mm
- length: 30mm
Rod-type heater
- power: 250W
- diameter: 8mm
- length: 130mm
Dimensions and Weight
LxWxH: 1.050x200x320mm
Weight: approx. 10kg
Scope of Delivery
1 experimental unit
1 manual