Data acquisition unit SAD450

It is connected to the PC via serial interface RS232C or USB (by adapter) and is controlled by an open protocol using ASCII commands, thus enabling made to measure software to be designed.

ANALOGUE INPUTS:

  • 8 inputs of 12-bit resolution.
  • Variable input voltage range between ±0.2V, ±0.5V, ±1V, ±2V, ±5V, ±10V programmable

DIGITAL OUTPUTS:

  • 16 digital outputs TTL (0-5V).

CONVERSION TIMES:

  • Fmax 1 analogue channel 200 Khz.
  • Fmax 1 digital channel 333 Khz.

ANALOGUE OUTPUTS:

  • 4 outputs of 9-bit resolution (8bits+Sign).
  • Output voltage range ±10V.

DIGITAL INPUTS:

  • 16 digital inputs TTL (0-5V).
  • 2 rapid counting inputs.

 

Connecting interface SAD451

This interface is a 2mm socket adaptor for all the inputs/outputs on the data acquisition system. It is divided into blocks according to the type of input/ output.

Signal conditioners

These are connected directly to the SAD451 and enable signals from outside to be conditioned to both the physical and electrical characteristics on it. Conditioners included with the unit:

1 SAD430: Screw connection for 8 digital inputs.

2 SAD431: Screw connection for 8 digital outputs.

3 SAD460: Perforated plate for prototypes (2 analogue inputs).

4 SAD461: Screw connection for 2 analogue inputs.

5 SAD462: BNC connection for 2 analogue inputs.

6 SAD463: Screw connection for 2 analogue outputs.

kaptoris_sad_450_sobremesa_d

 

Case for the unit

The SAD unit (desktop) is supplied with a case for better protection, handling and use. All the components for the unit and the KAPTORIS software are housed in this case.

DESCRIPTION

Ref.: 9EQKAPTORI

This system is made up of three components that enable it to be adapted easily to the requirements of the various systems to be analysed.

FEATURES

Data acquisition unit SAD450

It is connected to the PC via serial interface RS232C or USB (by adapter) and is controlled by an open protocol using ASCII commands, thus enabling made to measure software to be designed.

ANALOGUE INPUTS:

  • 8 inputs of 12-bit resolution.
  • Variable input voltage range between ±0.2V, ±0.5V, ±1V, ±2V, ±5V, ±10V programmable

DIGITAL OUTPUTS:

  • 16 digital outputs TTL (0-5V).

CONVERSION TIMES:

  • Fmax 1 analogue channel 200 Khz.
  • Fmax 1 digital channel 333 Khz.

ANALOGUE OUTPUTS:

  • 4 outputs of 9-bit resolution (8bits+Sign).
  • Output voltage range ±10V.

DIGITAL INPUTS:

  • 16 digital inputs TTL (0-5V).
  • 2 rapid counting inputs.

 

Connecting interface SAD451

This interface is a 2mm socket adaptor for all the inputs/outputs on the data acquisition system. It is divided into blocks according to the type of input/ output.

Signal conditioners

These are connected directly to the SAD451 and enable signals from outside to be conditioned to both the physical and electrical characteristics on it. Conditioners included with the unit:

1 SAD430: Screw connection for 8 digital inputs.

2 SAD431: Screw connection for 8 digital outputs.

3 SAD460: Perforated plate for prototypes (2 analogue inputs).

4 SAD461: Screw connection for 2 analogue inputs.

5 SAD462: BNC connection for 2 analogue inputs.

6 SAD463: Screw connection for 2 analogue outputs.

kaptoris_sad_450_sobremesa_d

 

Case for the unit

The SAD unit (desktop) is supplied with a case for better protection, handling and use. All the components for the unit and the KAPTORIS software are housed in this case.