FEATURES:
- Easy operation with UP/DOWN key
- High resolution: 10mV, 1mA
- Over voltage protection, over current protection by software
- 50 Sets memory
- Self test and software calibration
- Meets UL, CSA, IEC safety regulation
- Auto step running with timer setting
- Triple output
- Auto tracking
- RS-232 communication
- High stability,low drift
- 4 digit display
The PPE/PPT Series are 3-channel, programmable linear DC power supplies with 207/138/126W outputs. The PPE/PPT Series feature OVP and OCP protection and are compliant with all major safety standards (UL, CSA, and IEC) for safe, reliable operation. For extra precision, the PPT Series include remote sensing that adds an extra level of precision by compensating cable losses between loads. The digital interface and smart features simplify operation and configuration, such as output limit store/recall functions, automatic tracking, automatic tracking, automatic series or parallel operation (PPT-Series), and auto stepping for continuous testing. The series have Labview drivers and SCPI commands as standard for remote control and PC interfacing via RS232(PPE-3323) and GPIB(PPT-Series). The Versatile PPE/PPT-Series are ideal for high-level applications requiring high resolution, multiple outputs, and an extra level of safety.
OUTPUT |
|
Voltage | 0~+32V, 0~-32V, 3.3V/5V Fixed |
Current | 0~+3A, 0~-3A, 3A Fixed |
OVP | 0~+33V, 0~-33V |
LOAD REGULATION |
|
Voltage | < 6mV |
Current | < 3mA |
LINE REGULATION |
|
Voltage | < 3mV |
Current | < 3mA |
RESOLUTION |
|
Voltage | 10mV ( 20mV rating voltage > 36V ) |
Current | 1mA ( 2mA rating current >3.5A ) |
OVP | 10mV( 20mV rating voltage > 36V ) |
PROGRAM ACCURACY (25±5° C) |
|
Voltage | < 0.05% + 25mV ( + 50mV rating voltage > 36 V ) |
Current | < 0.2% + 10mA |
OVP | < 2% + 0.6V |
RIPPLE & NOISE (20Hz ~ 20MHz) |
|
Voltage | Ripple 1mVrms / 3mVp-p Noise 2mVrms / 30mVp-p |
Current | < 3mA rms ( < 5mA rms rating current > 3.5A ) |
TEMPERATURE (0~40° C ) COEFFICIENT |
|
Voltage | < 100ppm + 3mV |
Current | < 150ppm + 3mA |
READBACK RESOLUTION |
|
Voltage | 10mV ( 20mV rating voltage > 36V ) |
Current | 1mA ( 2mA rating current > 3.5A ) |
READBACK ACCURACY (25±5° C) |
|
Voltage | < 0.05% + 25mV ( + 50mV rating voltage > 36V ) |
Current | < 0.2% + 10mA |
RESPONSE TIME |
|
Voltage Up(10%~90%) | < 100mS |
Voltage Down(90%~10%) | < 100mS (≧ rating load) |
READBACK TEMPERATURE COEFFICIENT |
|
Voltage | < 100ppm + 10mV ( + 20mV rating voltage > 36V ) |
Current | < 150ppm + 10mA |
DRIFT |
|
Voltage | ≦ 100 ppm+10mV |
Current | ≦ 150 ppm+10mA |
TRACK OPERATION |
|
Tracking Error | < 0.1% + 50mV |
Series Regulation | < 50mV |
MEMORY |
|
Store / Recall 50 sets | |
TIMER |
|
Setting time | 1 sec ~ 99 min ( Max 99 min x 50 sets) |
Resolution | 1 sec |
Function | for output working loop ( Auto Step Running) |
INTERFACE |
|
RS-232 | |
POWER SOURCE | |
AC100V/120V/220V/240V±10%, 50/60Hz | |
ACCESSORIES |
|
User manual x 1 Power cord x 1 Test lead GTL-105 x 3 |
|
DIMENSIONS & WEIGHT | |
255(W) x 145(H) x 346(D)mm Approx. 10 kg |