For more info: sales@tangkasanugerah.com

Home / Products

GSP 9330 series

Features

  • Frequency Range: 9kHz ~ 3.25GHz
  • 0.025ppm Frequency Stability and 1ppm aging Rate
  • RBW: 1Hz ~ 1MHz (3dB), 6dB EMI Filter: 200Hz, 9kHz, 120kHz, 1MHz
  • Fastest sweep time: 204us
  • Sensitivity: -149 dBm/Hz (@PreAmp on)
  • Built-in Preamplifier, 50dB Attenuator, and Sequence Function
  • Built-in EMC pretest function, Quasi-Peak/Average EMI detect mode
  • Built-in 2FSK Analysis, AM/FM/ASK/FSK Demodulation & Analysis
  • Built-in P1dB point, Harmonic, CHPW, OCBW, ACPR, SEM, TOI, CNR, CTB, CSO, N-dB bandwidth, Noise Marker, Frequency Counter, TDP, Gated Sweep
  • Built-in Spectrogram, Topographic and Split-Window Display Modes
  • Remote control EMI measurement software: SpectrumShot
  • Remote Control Interface: LAN, USB, RS-232
  • Options: Tracking Generator, GPIB Interface, Battery Pack

DESCRIPTION

The brand new GSP-9330, a high test speed spectrum analyzer with 3.25 GHz, provides the fastest 204 μs sweep speed. Users, via high speed sweep time, can easily handle and analyze modulation signals.  The keys to handling modulated signals are fast sweep time and signal demodulation function. In addition to the analog AM/FM demodulation and analysis function, GSP-9330 also provides digital signal ASK/FSK, and 2FSK demodulation and analysis capabilities. 

FEATURES

Frequency

Frequency

Range

9 kHz to 3.25 GHz

Resolution

1 Hz

Frequency Reference

Accuracy

±(period since last adjustment X aging rate) + stability over temperature + supply voltage stability

Aging Rate

±1 ppm max.

1 year after last adjustment

Frequency Stability over Temperature

±0.025 ppm

0 to 50 °C

Supply Voltage Stability

±0.02 ppm

 

Frequency Readout Accuracy

Start, Stop, Center, Marker

±(marker frequency indication X frequency reference accuracy + 10% x RBW + frequency resolution)

Trace points

Max 601 points, min 6 points

Marker Frequency Counter

Resolution

1 Hz, 10 Hz, 100 Hz, 1 kHz

Accuracy

±(marker frequency indication X frequency reference accuracy + counter resolution)

RBW/Span >=0.02 ;

Mkr level to DNL>30 dB

Frequency Span

Range

0 Hz (zero span), 100 Hz to 3.25 GHz

 

Resolution

1 Hz

 

Accuracy

± frequency resolution1

RBW: Auto;

Phase Noise

Offset from Carrier

 

Fc =1 GHz; RBW = 1 kHz, VBW = 10 Hz; Average ≥ 40

10 kHz

<-88 dBc/Hz

Typical

100 kHz

<-95 dBc/Hz

Typical

1 MHz

<-113 dBc/Hz

Typical

Resolution Bandwidth (RBW) Filter

Filter Bandwidth

1 Hz to 1 MHz in 1-3-10 sequence

-3dB bandwidth

200 Hz, 9 kHz, 120 kHz, 1MHz

-6dB bandwidth

Accuracy

± 8%, RBW = 1MHz

Nominal

± 5%, RBW < 1MHz

Nominal

Shape Factor

< 4.5:1

Normal Bandwidth ratio: -60dB:-3dB

Video Bandwidth (VBW) Filter

Filter Bandwidth

1 Hz to 1 MHz in 1-3-10 sequence

-3dB bandwidth

Amplitude

Amplitude Range

Measurement Range

100 kHz to 1 MHz

Displayed Average Noise Level (DANL) to 18 dBm

1 MHz to 10 MHz

DANL to 21 dBm

10 MHz to 3.25 GHz

DANL to 30 dBm

Attenuator

Input Attenuator Range

0 to 50 dB, in 1 dB step

Auto or manual setup

Maximum Safe Input Level

Average Total Power

≤ +33 dBm

Input attenuator 
≥10 dB

DC Voltage

± 50 V

 

1 dB Gain Compression

Total Power at 1st Mixer

> 0 dBm

Typical;Fc  ≥ 50 MHz; preamp. off

Total Power at the Preamp

> -22 dBm

Typical;Fc  ≥ 50 MHz; preamp. on

 

mixer power level (dBm)= input power (dBm)-attenuation (dB)

Displayed Average Noise Level (DANL)

Preamp off

0 dB attenuation; RF Input is terminated with a 50Ω load. RBW 10 Hz; VBW 10 Hz; span 500 Hz; reference level =  -60dBm; trace average ≥ 40

9 kHz to 100 kHz

< -93 dBm

Nominal

100 kHz to 1 MHz

< -90 dBm - 3 x (f/100 kHz) dB

1 MHz to 2.7 GHz

< -122 dBm

2.7 GHz to 3.25 GHz

< -116 dBm

Preamp on

0 dB attenuation; RF Input is terminated with a 50Ω load ; RBW 10 Hz; VBW 10Hz; span 500 Hz;  reference level =  -60dBm; trace average ≥ 40

100 kHz to 1 MHz

< -108 dBm - 3 x (f/100 kHz) dB

Nominal

1 MHz to 10 MHz

< -142 dBm

10 MHz to 3.25 GHz

< -142 dBm + 3 x (f/1 GHz) dB

Level Display Range

Scales

Log, Linear

 

Units

dBm, dBmV, dBuV, V, W

 

Marker Level Readout

0.01 dB

Log scale

 

0.01 % of reference level

Linear scale

Level Display Modes

Trace, Topographic, Spectrogram

Single / split Windows

Number of Traces

4

 

Detector

Positive-peak, negative-peak, sample,  normal, RMS(not Video), Average(EMI), Quasi-Peak(EMI)

Can be setup for each trace separately

Trace Functions

Clear & Write, Max/Min Hold, View, Blank, Average

 

Absolute Amplitude Accuracy

Absolute Point

Center=160 MHz ; RBW 10 kHz; VBW 1 kHz; span 100 kHz; log scale;  1 dB/div; peak detector; 23°C±1°C; Signal at Reference Level

Preamp off

± 0.3 dB

Ref level 0 dBm; 
10 dB RF attenuation

Preamp on

± 0.4 dB

Ref level -30 dBm; 
0 dB RF attenuation

Frequency Response

Preamp off

Attenuation: 10 dB; Reference: 160 MHz; 20 to 30°C

100 kHz to 2.0 GHz

± 0.5 dB

 

2GHz to 3.25 GHz

± 0.7 dB

 

Preamp on

Attenuation: 0 dB; Reference: 160 MHz; 20 to 30°C

1 MHz to 2 GHz

± 0.6 dB

 

2 GHz to 3.25 GHz

± 0.8 dB

 

Attenuation Switching Uncertainty

Attenuator setting

0 to 50 dB in 1 dB step

 

Uncertainty

± 0.25 dB

reference: 160 MHz, 10dB attenuation

RBW Filter Switching Uncertainty

1 Hz to 1 MHz

± 0.25 dB

reference : 10 kHz RBW

Level Measurement Uncertainty

Overall Amplitude Accuracy

± 1.5 dB

20 to 30°C; frequency > 1 MHz; Signal input 0 to -50 dBm; Reference level  0 to -50 dBm; 
Input attenuation 10 dB;  
RBW  1 kHz; VBW 1 kHz; after cal; Preamp Off

± 0.5 dB

Typical

Spurious Response

Second Harmonic Intercept

 

Preamp off; signal input -30dBm; 0 dB attenuation

+35 dBm

Typical; 10 MHz < fc < 775 MHz

+60 dBm

Typical; 775 MHz ≤ fc < 1.625 GHz

Third-order Intercept

 

Preamp off; signal input -30dBm; 0 dB attenuation

> 1dBm

300 MHz to 3.25 GHz

Input Related Spurious

< -60 dBc

Input signal level -30 dBm, Att.

Mode, Att=0dB; 20-30ºC

Residual Response (inherent)

<-90 dBm

Input terminated; 0 dB attenuation; Preamp off

Sweep

Sweep Time

Range

204 us to 1000 s

Span > 0 Hz

50 us to 1000 s

Span = 0 Hz; Min Resolution = 10 us

Sweep Mode

Continuous; Single

 

Trigger Source

Free run; Video; External

 

Trigger Slope

Positive or negative edge

 

RF Preamplifier

 

Frequency Range

1 MHz to 3.25 GHz

 

Gain

18 dB

Nominal

 

(installed as standard)

Front Panel Input/Output

RF Input

Connector Type

N-type female

 

Impedance

50 ohm

Nominal

VSWR

<1.6 :1

300 kHz to 3.25 GHz; Input attenuator ≥ 10 dB

Power for Option

Connector Type

SMB male

 

Voltage/Current

DC +7V / 500 mA max

With short-circuit protection

USB Host

Connector Type

A plug

 

Protocol

Version 2.0

Supports Full/High/Low speed

MicroSD Socket

Protocol

SD 1.1

 

Supported Cards

 microSD, microSDHC

Up to 32GB capacity

Rear Panel Input/Output

Reference Output

Connector Type

BNC female

 

Output Frequency

10 MHz

Nominal

Output Amplitude

3.3V CMOS

 

Output Impedance

50 ohm

 

Reference Input

Connector Type

BNC female

 

Input Reference Frequency

10 MHz

 

Input Amplitude

-5 dBm to +10 dBm

 

Frequency Lock Range

Within ± 5 ppm of the input reference frequency

 

Alarm Output

Connector Type

BNC female

Open-collector

Trigger Input/ Gated Sweep Input

Connector Type

BNC female

 

Input Amplitude

3.3V CMOS

 

Switch

Auto selection by function

 

LAN TCP/IP Interface

Connector Type

RJ-45

 

Base

10Base-T; 100Base-Tx; Auto-MDIX

USB Device

Connector Type

B plug

For remote control only; supports USB TMC

Protocol

Version 2.0

Supports Full/High/Low

speed

IF Output

Connector Type

SMA female

 

Impedance

50 ohm

Nominal

IF Frequency

886 MHz

Nominal

Output level

-25 dBm

10 dB attenuation; RF input: 0 dBm @ 1 GHz

Earphone Output

Connector Type

3.5mm stereo jack, wired for mono operation

Video Output

Connector Type

DVI-I ( integrated analog and digital) , Single Link. Compatible with VGA or HDMI standard  through adapter

RS232 Interface

Connector Type

D-sub 9-pin female

Tx,Rx,RTS,CTS

GPIB Interface (Optional)

Connector Type

IEEE-488 bus connector

 

AC Power Input

Power Source

AC 100 V to 240 V, 50 / 60 Hz

Auto range selection

Battery Pack (Optional)

Battery pack

6 cells, Li-Ion rechargeable, 3S2P

With UN38.3 Certification

Voltage

DC 10.8 V

 

Capacity

5200 mAh / 56Wh

 

General

 

Internal Data storage

16 MB nominal

 

Power Consumption

<65 W

 

Warm-up Time

< 30 minutes

 

Temperature Range

+5 °C to +45 °C

Operating

-20 °C to + 70 °C

Storage

Weight

4.5 kg (9.9 lb)

Inc. all options (Basic+TG+GPIB+Battery)

Dimensions

210 x 350 x 100 (mm)

Approximately

 

8.3 x  13.8 x 3.9 (in)

 

Tracking Generator (Optional)

 

Frequency Range

100 kHz to 3.25 GHz

 

Output Power

-50 dBm to 0 dBm in 0.5 dB steps

Absolute Accuracy

± 0.5 dB

@160 MHz, -10 dBm, Source attenuation 10 dB, 20 to 30°C

Output Flatness

Referenced to 160 MHz, -10 dBm

100 kHz to 2 GHz

± 1.5 dB

2 GHz to 3.25 GHz

± 2 dB

Output Level Switching Uncertainty

± 0.8 dB

Referenced to -10 dBm

Harmonics

< -30 dBc

Typical, output level = -10 dBm

Reverse Power

+30 dBm max.

 

Connector type

N-type female

 

Impedance

50 ohm

Nominal

Output VSWR

< 1.6:1

300 kHz to 3.25 GHz, source attenuation ≥ 12 dB

Subscribe now