- Low Noise Floor(-117dBm@1GHz, 3k RBW)
- Sequence Programming Functions
- ACPR, OCBW, Channel Power, N-dB and Phase Jitter Measurements
- 10 Markers with Delta Marker, Peak Functions
- AC/DC/Battery(Option)three modes of power supply
- USB/RS-232C/GPIB(Option) Interface
- 6.4" TFT Color LCD, Resolution: 640x480
- Optional Tracking Generator
- Optional Preamplifier

DESCRIPTION

Featuring high performance, uncompromised design, and remote monitoring software, the GSP-830 3GHz Spectrum Analyzer is the latest evolution from GWInstek. The GSP-830 is one of the most advanced Spectrum Analyzer GWInstek has produced to date. The GSP-830 has an exceptional noise floor of -152dBm/Hz; combined with the optional GAP-802 preamplifier, the noise floor can reach a remarkable -172dBm/Hz. With a low noise floor, the GSP-830 is more than capable of finding limits; Trace Detection, combined with an easy-to-use interface, makes the GSP-830 an ideal solution for spectrum analysis. Using the Auto Sequence mode, advanced users can define their own macros in 10 Sequence sets. Repeat or Single run mode can be used to streamline repetitive tasks. PC connection is effortless and versatile supporting USB host/device, RS232C, VGA and GPIB (optional) for remote monitoring, control and analysis.

KEY FEATURES

GW Instek now extends its Spectrum Analyzer product series up to 3GHz. As a new member, the GSP-830 inherits the advantages of high performance, affordable cost, ease of use, and light-weight portability, which are common in GW Instek products. Moreover, its extremely low noise floor greatly increases the measurement range, an advanced user interface brings a significant visual enhancement, and the rich measurement functions make measurements simple and easy. The GSP-830 offers the greatest performance/price value in the market.

Wide Measurement Range
With GW Instek's state-of-the-art design, the GSP-830's outstanding low noise floor level of -152dBm/Hz at 1GHz has extreme sensitivity for picking up weak signals. Along with the GAP-802 20dB-gain preamplifier, the GSP-830 reaches an equivalent noise floor level as low as -172dBm/Hz, further extending the measurement range.

Automatic Measurement
The GSP-830 can act as an automatic test instrument to eliminate the need for external computer control. Macros can be defined through the front panel keypad and stored into 10 Sequence sets. A sequence can include pause steps that can be used for observing the measurement results when necessary. Repeat or Single run mode can be selected based on application requirements.

Portable Power Operations
Equipped with two packs of Li-ion batteries, the GSP-830 can maintain normal operation for more than 3 hours. In DC operation mode, the GSP-830 can be powered by a 12-Volt power supply or a standard cigarette lighter in an automobile. The large internal memory of the GSP-830 means mass storage of measured traces, setup information, limit lines and user-defined macros is possible. With USB flash drive support for mass storage, weighing 6kg and a compact size, the GSP-830 is also a convenient tool for service engineers out in the field.

Advanced User Interface
The user-oriented interface design of the GSP-830 gives users the pleasure of handling complicated measurements with ease. A high-resolution 6.4" color TFT LCD provides crisp and clear images. Colored, user-defined traces allow small disparities to be seen at a glance. The Split-Window mode allows simultaneous monitoring of two different frequency bands on a single display. Under this split-window mode, the GSP-830 acts like two spectrum analyzers packed into single unit.

Feature-Rich Interface
The USB host port on the front panel supports flash drives for various functions, including loading/saving setup information, tracing data, and capturing screens. The rear panel USB slave port is used for PC remote control. The GSP-830's screen image can be sent directly to external monitors through the VGA port on the rear panel. These features make it easy to remotely monitor the results in special circumstances, such as EMI testing, group presentations, or discussions.

Free PC Software for the GSP-830
Through RS-232 or USB connection, EagleShot can transfer measurement data from the GSP-830 to a PC. Data can be printed as graphs or saved as a text file for further analysis. With the EagleShot software, the limit lines can be uploaded from the GSP-830 or edited directly on the PC. For marking and reading the captured signals on the PC screen, markers can be placed directly on the PC display as easily as doing it on the GSP-830 front panel. The latest version of EagleShot supports the GSP-830 in various application fields whilst maintaining compatibility with the GSP-827.

FEATURES

FREQUENCY
Frequency Range 9kHz ~ 3GHz
Aging Rate ± 10ppm, 0~50°C, 5ppm/yr
Span Range 2kHz ~ 3GHz in 1-2-5 sequence, full span, zero span
Phase Noise -80dBc/Hz @1GHz 20kHz offset typical
Sweep Time Range 50ms ~ 25.6s
RESOLUTION BANDWIDTH
RBW Range 3kHz, 30kHz, 300kHz, 4MHz
RBW Accuracy 15%
Video Bandwidth Range 10Hz ~ 1MHz in 1-3 steps
AMPLITUDE
Measurement Range -103dBm ~ +20dBm: 1MHz ~ 15MHz, Ref.Level @ -30dBm 
-117dBm ~ +20dBm: 15MHz ~ 1GHz, Ref.Level ≧-110dBm 
-114dBm ~ +20dBm: 1GHz ~ 3GHz, Ref.Level ≧-110dBm 
(Span = 50kHz, RBW = 3kHz)
Overload Protection Max. +30dBm, ±25VDC
Reference Level Range -110dBm ~ +20dBm
Accuracy ±1dB @100MHz
Frequency Flatness ±1dB
Display Range Linearity ±1dB over 70dB
DYNAMIC RANGE
Average Noise Floor <-135±1dBm/Hz: 1MHz ~ 15MHz, Ref.Level @ -30dBm 
<-149dBm/Hz, typical -152dBm/Hz: 15MHz ~ 1GHz, Ref.Level ≧-110dBm 
<-146dBm/Hz, typical -149dBm/Hz: 1GHz ~ 3GHz, Ref.Level ≧-110dBm
Third Inter-Modulation <-70dBc RF Input @-40dBm, Ref.Level @-30dBm
Harmonic Distortion <-60dBc RF Input <-40dBm Typical, Ref.Level @-30dBm
Non-Harmonic Spurious <-93dBm, 1MHz ~ 15MHz, Ref.Level @-30dBm
<-107dBm ~ +20dBm: 15MHz ~ 1GHz, Ref.Level ≧-110dBm 
<-104dBm ~ +20dBm: 1GHz ~ 3GHz, Ref.Level ≧-110dBm 
(Span = 50kHz, RBW = 3kHz)
GENERAL
Display 640 x 480 high resolution TFT color LCD
Split Windows Active Window: Upper, Lower or Alternate (two simultaneously sweeping windows)
Markers 10 Markers for peaks: 5 normal-delta marker pairs
Functions: Delta, To Peak, To Minimum, Peak Track, Peak Table, Peak Sort
Trace Detection 3 traces with Peak, Maximum hold, Freeze, Average, Trace math
Power Measurement ACPR, OCBW, Channel Power, N dB and Phase Jitter
Autoset Function Auto tuning the measurement result for observation
Trigger Conditions: Video, External (Positive-going, +5V TTL external signal) 
Mode: Normal, Single, Continuous
 
Sequence Automated test by user-defined macros without any remote controller, 10 Sequential macro set and 10 macros per each set, Variable delays and wait-to-go facilitate automated measurement, Do-sequence links and nests different sequence sets.
CONNECTORS
RF Input
 
N female, 50Ω nominal
RF input VSWR: <2:1, @0dBm Reference Level
External Reference Type: BNC female
Clock Input 1M, 1.544M, 2.048M, 5M, 10M, 10.24M, 13M, 15.36M, 15.4M, 19.2MHz
Reference Clock Output Type: BNC female, 10MHz
DC Input (DC Power Operation) Jack : 5.5mm, 12V
DC Output (for GAP-801) Type: SMB Male, outputs +9V/100mA Max.
INTERFACE
RS-232C Sub-D 9 pins female
USB Connector USB Host/Device full speed supported
VGA Output Front panel: Type A receptacle for USB flash devices
Option: GPIB Interface Fully programmable with IEEE 488.2 compliance
POWER SOURCE  
  AC 100 ~ 240V, 50/60Hz
ACCESSORIES
  User Manual x 1
Power Cord x 1
USB Cable (Type A plug to Type mini-B plug) x1
DIMENSIONS & WEIGHT
  330(W) x 170(H) x 340(D) mm
Approx. 6kg
 

 

 

Opt. 01 Tracking Generator - Frequency Range: 9k~3GHz
- Amplitude Range: -50dBm~0dBm
- Amplitude Accuracy: ±1dB@100MHz, 0dBm
- Amplitude Flatness: ±1dB@0dBm
- Harmonics: <-30dBc typical
- Reverse Power: +30dBm
- Impedance: Type: N female, 50Ω nominal
- RF output VSWR: < 2:1
Opt. 02 Battery pack *  11.1V Li-Ion battery pack *2
Opt. 03 ± 1ppm Stability *   ±1ppm, 0~50 °C , ±1ppm/yr
Opt. 04 300Hz RBW *   RBW 300Hz, 3dB bandwidth, RBW Accuracy: 20%
Opt. 05 EMI Filter 9kHz & 120kHz RBW(*) *   RBW selections: 9kHz & 120kHz, 6dB bandwidth, Accuracy: 15%
Opt. 06 10kHz & 100kHz RBW (*) *   RBW selections: 10kHz & 100kHz, 3dB bandwidth,  Accuracy: 15%
Opt. 07 Demodulator (*) * Demodulation: AM/ FM
* Output: Internal speaker, 3.5mm stereo jack wired for mono operation
* RBW selection: 10kHz & 100kHz, 3dB bandwidth, Accuracy: 15%
Opt. 08 GPIB Interface *   IEEE 488 bus
Note:
1. (*) Only one option can be selection between Opt. 05, 06, 07
2. All options are factory-installed except opt.02.

 

 

 

 

OPTIONAL ACCESSORIES
ATA-001 BNC Antenna
(An additional ADP-001 is needed for fitting GSP spectrum analyzers)
ATA-002 Near Field Probe
(An additional ADP-001 & GTL-110 is needed for fitting GSP spectrum analyzers)
GAP-801 Preamplifier Preamplifier with 10dB(typical), gain 9kHz ~ 6GHz
GAP-802 Preamplifier Preamplifier with 20dB(typical), gain 9kHz ~ 3GHz
RLB-001 Return Loss Bridge RLB Frequency Range 10MHz ~ 1GHz
GTP-3000 Passive touch Probe Set
PR-03: Passive touch probe, SMA(F)
ADP-002: Adaptor, SMA(J/F) ~ N(P/M)
GTL-303: RF Cable Assembly, SMA(P/M), 600mm
GKT-001 General Kit set
ADP-002: adaptor, SMA(J/F) ~ N(P/M) x 2
ATN-100: 10dB attenuator, N(J/F) ~ N(P/M) x 1
GTL-303: RF cable assembly(SMA(P/M),RD316,600mm)x2
GSC-002: Kit box x 1
GKT-002 CATV Kit set
ADP-001: adaptor, BNC(J/F) ~ N(P/M) x 2
ADP-101: adaptor, BNC(J/F)75Ω ~ BNC(P/M)50Ωx 2
GTL-304: RF cable assembly(RG223,N(P/M)-N(J/F),300mm)x2
GSC-003: Kit box x 1
GKT-003 RLB Kit set
GAK-001: termination 50 , N(P/M) x 1
GAK-002: Cap with chain, N(P/M) x 1
GTL-302: RF cable assembly(RG223,N(P/M),300mm)x2
GSC-004: Kit box x 1
GKT-006 EMI Probe Kit set
ANT-01: 6cm Loop, H-Field Probe x 1
ANT-02: 3cm Loop, H-Field Probe x 1
ANT-03 6mm Stub tip, E- Field Probe x 1
PR-03: Touch Passive Probe x 1 ADP-02: N(P/M)~SMA(J/F) Adapter x 1
ADP-01: N(P/M)~BNC(J/F) Adapter x 1
Test Lead: BNC(P/M)~BNC(P/M) RF Cable x 1
Test Lead: SMA(P/M)~SMA(P/M) RF Cable x 1
GRA-404 Rack Adapter Panel
Rack Mounting (19", 4U)
GSC-001 Soft Carrying Case
GTL-301 RF Cable RG 223 N(P/M), 1000mm
GTL-401 DC Power Cord
DC power cord with DC Jack and lighter plug, Current 5A

 

 