For more info: sales@tangkasanugerah.com
FEATURES:
- 0.01% High Regulation
- Constant Voltage and Constant Current Operation
- Low Ripple and Noise
- Overload and Reverse Polarity Protection
- 3 1/2 Digits 0.5" LED Display
- Application for Material and Products Aging
- Built-In Overvoltage and Overcurrent Tripped Crowbar
- Ten-Turn Potentiometer
The GPR-U Series are single output, 500 to 900W, linear DC power supply. Overload and reverse polarity protection, in addition to the standard OVP/OCP/OTP, protects the GPR-U Series and their load from unexpected conditions. High regulation and low ripple/noise are maintained at 0.01% and < 2mVrms, respectively for CV mode. The GPR-U Series can be ordered with a customized output requirement from voltage rating from 8 to 1000V and current rating from 0.5 to 75A, (under 1kVA available). The GPR-U Series are the ideal lineup for system applications requiring large output capacity or custom-made output settings, such as material testing and product copper plating.
SELECTION GUIDE | ||||
Output Watts (W)
|
Output Volts (V)
|
Output Amps (A)
|
Weight (kg)
|
|
GPR-1850HD
|
900W
|
0 ~ 18
|
0 ~ 50
|
30
|
GPR-3520HD
|
700W
|
0 ~ 35
|
0 ~ 20
|
29.5
|
GPR-6015HD
|
900W
|
0 ~ 60
|
0 ~ 15
|
30
|
GPR-7510HD
|
750W
|
0 ~ 75
|
0 ~ 10
|
29.5
|
GPR-16H50D
|
800W
|
0 ~ 160
|
0 ~ 5
|
30.5
|
GPR-25H30D
|
750W
|
0 ~ 250
|
0 ~ 3
|
29.5
|
GPR-35H20D
|
750W
|
0 ~ 350
|
0 ~ 2
|
29.5
|
GPR-50H15D
|
750W
|
0 ~ 500
|
0 ~ 1.5
|
29.5
|
GPR-60H15D
|
800W
|
0 ~ 600
|
0 ~ 1.5
|
30.5
|
GPR-100H05D
|
500W
|
0 ~ 1000
|
0 ~ 0.5
|
28.5
|
DC OUTPUT | ||
Output Volts (V) | Output Amps (A) | |
GPR-1850HD | 0 ~ 18 | 0 ~ 50 |
GPR-3520HD | 0 ~ 35 | 0 ~ 20 |
GPR-6015HD | 0 ~ 60 | 0 ~ 15 |
GPR-7510HD | 0 ~ 75 | 0 ~ 10 |
GPR-16H50D | 0 ~ 160 | 0 ~ 5 |
GPR-25H30D | 0 ~ 250 | 0 ~ 3 |
GPR-35H20D | 0 ~ 350 | 0 ~ 2 |
GPR-50H15D | 0 ~ 500 | 0 ~ 1.5 |
GPR-60H15D | 0 ~ 600 | 0 ~ 1.5 |
GPR-100H05D | 0 ~ 1000 | 0 ~ 0.5 |
CONSTANT VOLTAGE OPERATION | ||
Regulation | Line regulation ≦ 0.01% + 3mV Load regulation ≦ 0.01% + 5mV (<10A) Load regulation ≦ 0.02% + 5mV (≧10A) |
|
Ripple & Noise | ≦ 2mVrms (5Hz ~ 1MHz) | |
Recovery Time | ≦ 100μS ( 50% Load change, Minimum load 0.5A ) | |
Output range | 0 to rating voltage continuously adjustable | |
CONSTANT CURRENT OPERATION | ||
Regulation | Line regulation ≦ 0.2% + 3mA Load regulation ≦ 0.2% + 3mA |
|
Ripple Current | ≦ 5mArms (≦ 20A) ≦ 20mArms (≦ 50A) ≦ 100mArms (≦ 100A) |
|
Output Range | 0 to rating current continuously adjustable | |
METER | ||
Type | 3 1/2 Digits 0.5" LED Display | |
Accuracy | ± ( 0.5% of rdg + 2 digits ) | |
INSULATION | ||
Chassis and Terminal | 100MΩ or above (DC 1000V) | |
Chassis and AC Cord | 100MΩ or above (DC 1000V) | |
POWER SOURCE | ||
AC120V±10%, 50/60Hz ( AC 220V or 240V order made) |
||
ACCESSORIES | ||
User manual x 1 Test lead GTL-105 x 1 (≦3A), or GTL-104 x 1 (≦10A), or Not available (>10A or 600V) |
||
DIMENSIONS & WEIGHT | ||
430(W) x 178(H) x 572(D)mm Approx. 29.5kg |