For more info: sales@tangkasanugerah.com

Home / Products

APS 7000 Series

  • Features

    • 4.3-inch TFT-LCD
    • Output capacity : APS-7050(500VA、310Vrms、4.2Arms), APS-7100 (1000VA、310Vrms、8.4Arms), APS-7200(2000VA、310Vrms、16.8Arms), APS-7300 (3000VA、310Vrms、25.2Arms);Output augmentation by options (0~600Vrms/45~999.9Hz)
    • Low Ripple & Noise
    • Measurement and test functions include VOLT、CURR、PWR、SVA、IPK、IPKH、FREQ、PF、CF
    • Support a small AC current measurement 2mA ~ 35A, Min. resolution 0.01mA(APS- 7050& APS-7100)
    • Reverse Current Alarm Function
    • 10 sets of Sequence function to Edit Output Waveforms/ 10 sets of simulate mode to Rapidly Simulate Transient Power Supply/ 10 sets of Program mode to Define Measurement Sequence/ 10 sets of Panel Memory Function
    • Automatic Execution of Sequence、Simulate、Program mode and Output Function when the Power is on
    • Standard Interfaces: USB Host, USB Device, LAN
    • Optional Interfaces: GPIB (APS-001);RS-232 / USB CDC(APS-002 for APS-7050& APS-7100 only), RS-232(APS-007 for APS-7200& APS-7300 only)

DESCRIPTION

GWInstek introduces new APS-7000 series programmable AC power sources, which consists of 500VA of APS-7050, 1000VA of APS-7100, 2000VA of APS-7200 and 3000VA of APS-7300. APS-7000 series feature power characteristics from its linear structure design including low noise, low THD, and highly stabilized power output that are ideal for the product development and verification of input power with low noise requirement or stereo, video and audio device applications, etc. The maximum rated voltage is 0~ 310Vrms, 25.2Arms, 100.8A peak current and the output frequency range is 45~500.0Hz. Users can conveniently augment the output voltage from 0Vrms to 600Vrms and output frequency from 45Hz to 999.9Hz by purchasing options without sending equipment back to GW Instek.

 

One of the popular alternative energy solutions in the market is to utilize inverter to convert DC to AC and the converted AC is then sent to power grid or products require electricity. For instance, AC produced by PV inverter is sent to power grid or equipment requires electricity. While simulating power grid to verify inverter connecting with power grid, general AC power sources cannot withstand DUT’s feedback energy, hence, additional power consumption resistors are needed to prevent AC power source from being damaged. On the contrary, APS-7000 series have the characteristic of absorbing reverse current so that additional power consumption resistors are not required. The input terminal of APS-7000 series is designed to isolate from the simulated AC power grid output terminal, therefore, users do not need an additional isolation device to protect DUT. APS-7000 series are suitable for simulating power grid and conducting inverter output characteristic tests, including synchronized phase and frequency. Reverse current and power detected by APS-7000 series will be displayed in red readings to facilitate user’s test observation. APS-7000 series utilize Simulate mode and Sequence mode to provide a single step or consecutive power changes; and to simulate power grid’s Voltage Abnormality Test and Frequency Abnormality Test.    

APS-7000 series comprise nine measurement and test functions (Vrms, Irms, F, Ipk, W, VA, PF, Ipk hold, CF), and provide user interface similar to that of AC Power Meter.  APS-7000 series are ideal for the LED industry and standby mode power consumption test. Under the ARB mode, APS-7000 series provide waveforms in seven categories including Sine waveform, Triangle waveform, Staircase waveform(Square wave), Clipped Sinewave, Crest factor waveform, Surge waveform, and Fourier series and 20,000 waveform combinations so as to meet the requirements of simulating abnormal input power waveform test of various industries. Ten Preset settings allow users to store ten sets of data; Power ON Output setting allows Sequence, Simulate, and Program to automatically execute output after the equipment power is on.

 

To meet the test criteria of line voltage fluctuation often seen in consumer electronics, APS-7000 series feature five methods to cope with special purpose or abnormal voltage, frequency, and phase; ten sets of the Simulate mode simulate power outage, voltage rise, and voltage fall; ten sets of the Sequence mode allow users to define parameters and produce sine wave by editing steps; ten sets of the Program mode can edit AC waveform output and define the ceiling and floor level of measurement items for different DUTs; Ramp Control allows users to set the variation speed for output voltage rise and fall; Surge/Dip Control simulates DUT’s input power producing a Surge or Dip voltage overlapping with output voltage waveform at a specific time. For larger current output applications, voltage drop across the output cables should be avoided. APS-7200/7300 also provide the remote sense function, which senses DUT’s voltage and sends the information back to APS-7200/7300 for program controlled voltage compensation. Therefore, APS-7200/7300 can provide users with very accurate large current measurement applications.

 

Ethernet Port, on the rear panel, can be used for remote program control; Sync Output Socket provides external 10V sync output; Signal Output Connector provides monitor of Program execution results. APS-7000 series also provide users with Trigger In/Out and Output on/off remote control functions from J1 connector on the rear panel.

FEATURES

Model   APS-7050 APS-7100 APS-7200 APS-7300
AC OUTPUT
Power Rating 500VA 1000VA 2000VA 3000VA
Output Voltage 0 ~ 155Vrms, 0 ~ 310Vrms
Output Frequency 45.00 ~ 500.0 Hz
Max. Current(rms) *1 0 ~ 155 Vrms 4.2A 8.4A 16.8A 25.2A
0 ~ 310 Vrms 2.1A 4.2A 8.4A 12.6A
Max. Current (peak) 0 ~ 155 Vrms  16.8A 33.6A 67.2A 100.8A
 0 ~ 310 Vrms 8.4A 16.8A 33.6A 50.4A
OPT. APS-003(rms) 0 ~ 600 Vrms 1.05A  2.1A 4.2A 6.3A
OPT. APS-003(peak)  0 ~ 600 Vrms 4.2A 8.4A 16.8A 25.2A
Total Harmonic Distortion (THD) *2 ≤ 0.5% at 45 ~ 500.0Hz (Resistive Load)
Crest factor ≥ 4
Line regulation 0.1% (% of full scale)
Load regulation 0.5% (% of full scale)
Response time < 100µS
Reverse current 30% of Maximum Output RMS Current (Continue)
100% of Maximum Output RMS Current (Within 3 minutes)
SETTING
 Voltage    Range  0 ~ 155Vrms, 0 ~ 310Vrms, Auto   
 Resolution  0.01V at 0.00 ~ 99.99Vrms
  0.1V at 100.0 ~ 310.0Vrms   
 Accuracy  ± (0.5% of setting + 2 counts)   
 Frequency    Range  45 ~ 500 Hz   
 Resolution 0.01Hz at 45.00 ~ 99.99Hz
0.1Hz at 100.0 ~ 500.0Hz    
Accuracy  ± 0.02% of Setting    
Power on/off phase angle    Range  0 ~ 359°   
 Resolution 1°    
Accuracy ± 1° (Only 45 ~ 65Hz)
Measurement *3
Voltage (rms) Range 0.20 ~ 38.75Vrms
38.76 ~ 77.50Vrms
77.51 ~ 155.0Vrms
155.1 ~ 310.0Vrms
Resolution 0.01V at 0.00 ~ 99.99Vrms
0.1V at 100.0 ~ 310.0Vrms
Accuracy *4 ± (0.5% of reading + 2 counts)
Frequency Range 45 ~ 500Hz
Resolution 0.01Hz at 45.00 ~ 99.99Hz
0.1Hz at 100.0 ~ 500.0Hz
Accuracy ± 0.1Hz
Current (rms) Range 2.00 ~ 70.00mA
60.0 ~ 350.0mA
0.300 ~ 3.500A
3.00 ~ 17.50A
0.200 ~ 3.500A
3.00 ~ 35.00A
Resolution 0.01mA
0.1mA
0.001A
0.01A
0.001A
0.01A
Accuracy ± (0.6% of reading + 5 counts) , 2.00 ~ 350.0mA
± (0.5% of reading + 5 counts) , 0.300 ~ 3.500A
± (0.5% of reading + 3 counts) , 3.000 ~ 17.50A
± (0.5% of reading + 5 counts) , 0.200 ~ 3.500A
± (0.5% of reading + 3 counts) , 3.00 ~ 35.00A
Current (peak) Range 0.0 ~ 70.0A 0.0 ~ 140.0A
Resolution 0.1A 0.1A
Accuracy ± (1% of reading + 1 counts) ± (1% of reading + 1 counts)
Power (W)  Resolution 0.01W
0.1W
1W
0.1W
1W
Accuracy   ± (0.6% of reading + 5 counts) , 0.20 ~ 99.99W
± (0.6% of reading + 5 counts) , 100.0 ~ 999.9W
± (0.6% of reading + 2 counts) , 1000 ~ 9999W

± (0.6% of reading + 5counts) , 0.2 ~ 999.9W
± (0.6% of reading + 2counts) , 1000 ~ 9999W

Apparent Power (VA) Resolution 0.01VA
0.1VA
1VA
0.1VA
1VA
Accuracy ± (1% of reading + 7 counts) , 0.20 ~ 99.99VA
± (1% of reading + 7 counts) , 100.0 ~ 999.9VA
± (1% of reading + 5 counts) , 1000 ~ 9999VA
± (1% of reading + 7 counts) , 0.2 ~ 999.9VA
± (1% of reading + 5 counts) , 1000 ~ 9999VA
Power Factor Resolution 0.001
Accuracy ±2% reading + 2 counts
General
Remote output signal Pass, Fail, Test-in Process, Trigger in, Trigger out, OUT ON/OFF
Sync output signal Output Signal 10 V, BNC Type
Number of Preset 10 (0~9 numeric keys)
Protection OCP, OPP, OTP and Alarm
Trigger Out Maximum low level output = 0.8V
Minimum high level output = 2V
Maximum source current = 8mA.
Trigger In Maximum low level input voltage = 0.8V
Minimum high level input voltage = 2.0V
Maximum sink current = 8mA.
SEQUENCE / SIMULATION FUNCTION
Number of Memories 10 (0~9 numeric keys)
Number of Steps 255 max. (for 1 sequence)
Step Time Setting Range 0.01 ~ 999.99 S
Operation within Step Constant, Keep, Linear Sweep
Parameters Ouptut Range, Frequency, Waveform (sine wave only), On Phase, Off Phase,  Term Jump Count (0 ~255), Jump-to, Branch 1, Branch 2, Trigger Output
Sequence Control Start, Stop, Hold, Continue, Branch 1, Branch 2
AC Input
Phase Single Phase
Input Voltage 115/230Vac ± 15% 230Vac ± 15%
Input Frequency 50/60Hz
Max. Current 16A/8A 32A/16A 32A 50A
Power Factor 0.7 Typ.
Enviromental Conditions
Operating temperature range 0 ~ +40 ℃
Storage temperature range -10 ~ +70 ℃
Operating humidity range 20 ~ 80% RH (no condensation)
Storage humidity range 80% RH or less (no condensation)
Interface
Standard USB Host, LAN USB Host, USB CDC, LAN
Optional GPIB (APS-001)
RS232 / USB CDC (APS-002)
GPIB (APS-001)
RS232 (APS-007)
 Dimensions & Weight
Dimensions(mm) W 430 430 430 430
H 89 89 312 400
D 400 560 650 650
 Weight 24Kg 38Kg 90Kg 128Kg

 

Product specifications are subject to change without notice. 
The Specifications are not suit for ARB mode. 

*1 Maximun output current at working voltage 120Vrms, 240Vrms 
*2 45 to 500Hz, 10% or higher of the rated output voltage, the maximum current or lower 
*3 All of measurement accuracy is at 23±5℃ 
*4 In the case of 15 to 155V, 30 to 310V, sine wave, no load

Subscribe now


Loading...